CLICK TO ENLARGE IMAGE
 |
 |
CONTROL INTERFACE FROM LEVITON-NSI

MODEL NUMBER: #I/F 501

LEVITON-NSI CONTROL INTERFACE DESCRIPTION
The Leviton-NSI Control Interface is your simple solution for dimmer and control systems compatibility. The I/F 501 may be configured to combine and convert analog, multiplex and digital control signals (DMX512, CMX, AMX, Micro-Plex, Luma-net, MIDI, RS232 and 0-10V analog). In addition to converting a variety of control signals, the interface is pre-programmed as a stand alone auto sequence control device.

LEVITON-NSI CONTROL INTERFACE FEATURES
• 8 Pre-programmed auto sequence chases for stand-alone operation
• Programmable 20 cue sequence ASCII text files control 16 channels for stand-alone operation
• Interface between a computer and Luma-Net network for programming Luma-Net stations
• Trigger Luma-Net pre-sets with external contact closures

LEVITON-NSI CONTROL INTERFACE CONVERSION CAPABILITIES
• Micro-plex converts to DMX512
• Micro-plex converts to AMX192
• DMX512 converts to Micro-Plex
• DMX512 converts to AMX192
• Luma-Net® to Micro-Plex
• Luma-Net® to DMX512
• Luma-Net® to AMX192
• MIDI converts to Micro-Plex
• MIDI converts to DMX512
• MIDI converts to AMX192
• RS-232 converts to Micro-Plex
• RS-232 converts to DMX512
• RS-232 converts to AMX192
• 4 Channels 0-10V Analog converts to Micro-Plex
• 4 Channels 0-10V Analog converts to DMX512
• 4 Channels 0-10V Analog converts to AMX192

LEVITON-NSI CONTROL INTERFACE PORTS
• Micro-Plex in (3 pin XLR male)
• Micro-Plex out (3 pin XLR female)
• DMX512 in (5 pin XLR male)
• DMX512 out (5 pin XLR female)
• Optional AMX192 out (4 pin XLR male)
• RS-232 (9 pin D-Sub/DB9 male)
• MIDI in/0-10V analog in (5 pin DIN, 180 degree)
• Luma-Net (RJ14)

|